What is LM-80 report?

What is LM-80 report?

Oct 16, 2019

LM-80 is the Illuminating Engineering Society of North America (IESNA) approved standard for measuring lumen maintenance of LED light sources. LM-80-08 apply to the LED package, array, or module alone, not a complete system, it is testing a component level. The standard does not provide guidance for extrapolation of testing results.

Who can perform testing?
LM-80-08 testing should be performed by EPA recognized Laboratories. Only reports from recognized laboratories are relevant. This standard is used for Department Of Energy (DOE) ENERGY STAR program early qualification in conjunction with other reports. Most GREEN CREATIVE product use LED with available LM-80-08 test report from recognized laboratory.

What does it provide?
The testing report issued according to a standard format will provide luminous flux for a given current over a 6,000 hours period with interval measurements. Luminous flux will be measure for 3 different LED case temperatures: 55ºC, 85ºC and a third temperature to be selected by manufacturer. Besides, the lumen maintenance, the chromaticity shifts over the measured period.